High Voltage Insulation Assessment Based on a Mathematical Model of Transmission Line with Lightning Strike Simulation

Main Article Content

Anisa Kusuma Ningrum
I Made Yulistya Negara
Dimas Anton Asfani

Abstract

Lightning is a natural source that causes a major failure on power system especially in transmission line. It could decrease the reliability of the power system due to generating the overvoltage phenomenon which lead to insulator broken. When lightning strokes the tower or the ground wire, the effect of different lightning will have different consequences for voltage rise and affect to discharge process. During the discharge process, the voltage in each arm of tower will rise and lead to insulator being broken due to insulator being unable to withstand the current surge. Hence, the number of footing resistance took a crucial part during this process. Higher footing resistance will hinder the discharge process and affect the magnitude of voltage raises throughout the transmission lines. In PT. Vale Indonesia, the magnitude of footing resistance is varied and no standardized value to maintain the footing resistance value. The standardization of footing resistance is required to prevent large-scale failure from occurring in the system. This paper aimed to obtain the effect of direct strike in transmission tower and the optimum value of footing resistance to prevent large scale of failure that affect to production for PT. Vale Indonesia transmission line system considered by simulation from ATPDraw. 

Article Details

Section
Articles
Author Biography

Anisa Kusuma Ningrum, Institut Teknologi Sepuluh Nopember

An electrical engineer with 8 years experience in High Voltage until Low Voltage system

References

J. Hartono, M. Ridwan, M. M. Mafruddin, H. Habibi, and E. Anugrahany, “500 kV Quadruple Circuit Compact Transmission Line Redesign Study to Reduce the Impact of Lightning Strikes,” in 2021 3rd International Conference on High Voltage Engineering and Power Systems, ICHVEPS 2021, Institute of Electrical and Electronics Engineers Inc., 2021, pp. 263–267. doi: 10.1109/ICHVEPS53178.2021.9601020.

R. Saleh, A. Musyafa, and Busyairi, “Reliability evaluation with extended mast terminal (EMT) to protect Pt. Vale Indonesia 150 kV transmission line against back flash over and shielding failure of lightning impulse,” in AIP Conference Proceedings, American Institute of Physics Inc., Mar. 2019. doi: 10.1063/1.5095259.

“Electrical Power Transmission System Engineering Third Edition Analysis and Design.”

P. S. R. Murty, “Protection Against Overvoltages,” in Electrical Power Systems, Elsevier, 2017, pp. 259–275. doi: 10.1016/b978-0-08-101124-9.00012-7.

J. E. Guevara, J. S. L. Colqui, and J. P. Filho, “Analysis of Overvoltage and Backflashover with Different Transmission Line Models,” in Conference Proceedings - IEEE SOUTHEASTCON, Institute of Electrical and Electronics Engineers Inc., 2024, pp. 498–503. doi: 10.1109/SoutheastCon52093.2024.10500135.

Flashover Phenomenon on 150kV Transmission Line due to Direct Lightning Strike on the Ground Wire. Institute of Electrical and Electronics Engineers, 2018.

S. Hardi, F. Mirza, F. R. A. Bukit, and Rohana, “Influence of Lightning Characteristics on Back Flashover in Extra High Voltage Transmission Line: A case study,” in Journal of Physics: Conference Series, IOP Publishing Ltd, 2021. doi: 10.1088/1742-6596/1811/1/012048.

A. A. Kusuma, P. A. A. Prmana, B. S. Munir, and R. A. S, Studying of Lightning Surge Transient Effect on 500kV Quadruple Circuit Transmission Line. IEEE, 2016.

A. Kusuma, P. A. A. Pramana, B. S. Munir, and R. Ayu S, “Studying of Lightning Surge Transient Effect on 500kV Quadruple Circuit Transmission Line,” IEEE, 2016.

J. Hartono, M. Ridwan, M. M. Mafruddin, H. Habibi, and E. Anugrahany, “500 kV Quadruple Circuit Compact Transmission Line Redesign Study to Reduce the Impact of Lightning Strikes,” in 2021 3rd International Conference on High Voltage Engineering and Power Systems, ICHVEPS 2021, Institute of Electrical and Electronics Engineers Inc., 2021, pp. 263–267. doi: 10.1109/ICHVEPS53178.2021.9601020.

IEC-62305_Protection against lightning. Part 1, General principles. International Electrotechnical Commission, 2010.

Ravindra. Arora and Wolfgang. Mosch, High Voltage and Electrical Insulation Engineering. Wiley, 2011.

A. . Hileman, Insulation Coordination for Power Systems. Vol. 9. Taylor & Francis Group, 1999.

S. Hardi, F. Mirza, F. R. A. Bukit, and Rohana, “Influence of Lightning Characteristics on Back Flashover in Extra High Voltage Transmission Line: A case study,” in Journal of Physics: Conference Series, IOP Publishing Ltd, 2021. doi: 10.1088/1742-6596/1811/1/012048.

IEC 62305-1 Protection against lightning. Part 1, General principles. International Electrotechnical Commission, 2010.